Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE
- General Information
- Manufacturer
- Tripp Lite by Eaton
- Manufacturer Website Address
- https://tripplite.eaton.com/
- Brand Name
- Tripp Lite by Eaton
- Product Type
- Isolation Transformer
- Warranty
- Limited Warranty
- 2 Year
- Technical Information
- Power Rating
- 250 VA
- Output Receptacle Type
- NEMA 5-15R
- Output Receptacle Detail
- 2 x NEMA 5-15R
- Power Description
- Input Voltage
- 120 V AC
- Output Voltage
- 120 V AC
- Maximum Line Current
- 2.10 A
- Physical Characteristics
- Form Factor
- Tower
- Height
- 4.5"
- Width
- 4.8"
- Depth
- 7.8"
- Miscellaneous
- Additional Information
- Transformer Type: Medical grade, low impedance transformer-based line isolation transformer
- Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops
- Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
- Suppression Joule Rating: 680 (510 input/170 output)
- Leakage Current: As low as 100 microamps
- Noise Suppression Rating: 35 to 65 DB
- Total Harmonic Distortion: Less than 1%
- Over Current Protection: 2A circuit breaker
- Cooling Method: Convection
- Efficiency: 96%
- Let-through Voltage (Ring Wave):
- L-N: 20 V
- L-G: 20 V
- N-G: 0.5 V
- Let-through Voltage (Combination Wave):
- L-N: 250 V
- L-G: 250 V
- N-G: 0.5 V
- Package Contents
- IS250HG
- IS250HG Isolation Transformer
- Instruction manual with warranty information
- Certifications & Standards
- cUL
- UL 2601-1
- UL (UL Series AGIS250YWN)
- Country of Origin
- Taiwan
- TAA Compliant
- Yes