Tripp Lite by Eaton SmartOnline 208/240V 10kVA 9kW Double-Conversion UPS, 6U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch, NEMA

  • Part: 1242643
  • Model: SU10000RT3U
$8,981.00
FREE DELIVERY

Availability

Out of Stock

  • General Information
    • Manufacturer
    • Tripp Lite by Eaton
    • Manufacturer Website Address
    • https://tripplite.eaton.com/
    • Brand Name
    • Tripp Lite by Eaton
    • Product Line
    • SmartOnline
    • Product Type
    • Double Conversion Online UPS

Tripp Lite SU10000RT3U 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

More from the Manufacturer

  • Warranty
    • Limited Warranty
    • 2 Year

  • Technical Information
    • Plug/Connector Type
    • Hardwired
    • Receptacle Type
      • NEMA L6-20R
      NEMA L6-30R
    • Receptacle Detail
    • 2 x NEMA L6-30R
    • 4 x NEMA L6-20R
    • Transfer Time
    • 0 ns
  • Power Description
    • Load Capacity (VA)
    • 10000 VA
    • Input Voltage
    • 220 V AC
    • Output Voltage
    • 200 V AC
    • 220 V AC
    • 208 V AC
    • 230 V AC
    • 240 V AC
    • Input Frequency
    • 60 Hz
    • Output Frequency
    • 60 Hz
    • Waveform Type
    • Sine Wave
  • Management
    • Network Management
    • SNMP Manageable
    • Alarm
    • Backup Operation
    • Low Battery
    • Output Overload
    • Inverter Fault
    • DC Bus Fault
    • Over Temperature
    • Remote Shutdown
    • Shutdown Complete
    • UPS Start
    • Imminent Shutdown
    • Bypass Switch
    • Manual
    • Emergency Power OFF
    • Yes
  • Controls/Indicators
    • Status Indicators
    • LED Display:

      • Line power
      • Bypass
      • Inverter
      • Charger
      • Output AC
      • Battery operation
  • Battery Information
    • Backup/Run Time (Full Load)
    • 6 Minute
    • Backup/Run Time (Half Load)
    • 12 Minute
    • Typical Battery Recharge Time
    • 8 Hour
  • Environmental Conditions
    • Maximum Operating Temperature
    • 104°F (40°C)
    • Thermal Dissipation
    • 885.66 W
  • Physical Characteristics
    • Color Family
    • Black
    • Product Color
    • Black
    • Form Factor
    • Rack/Tower
    • Rack Height
    • 6U
    • Height
    • 31"
    • Width
    • 26"
    • Depth
    • 41"
    • Weight (Approximate)
    • 300 lb
  • Miscellaneous
    • Package Contents
      • Smart Online, SU10000RT3U, Expandable 10kVA Tower/Rack-mountable UPS System
      • 3U power module with detachable hot-swap PDU input/output panel and bypass switch
      • 3U external battery pack
      • Two sets of 4-post rackmount rails (one for each of the 3U components)
      • One set of tower stands for upright tower con
    • Additional Information
      • Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions
      • Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 156VAC, below this point, output is maintained utilizing battery reserves
      • High voltage transfer to battery power: Maintains continuous operation during overvoltages to 276V AC, above this point, output is maintained utilizing battery reserves
      • Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure
      • Voltage regulation description: On-line, double-conversion process give this UPS the ability to maintain output voltage within +/-2% of selected nominal voltage at all times
    • Certifications & Standards
    • Tested to UL1778 (USA), CSA (Canada), CE (European Union), NOM (Mexico), Class A (Emissions)

    • Software Included
    • PowerAlert Software
    • Country of Origin
    • China

You Might Also Like